Condition 2
WARNING: This page is about a different variant/trim than selected.
- No DTCs P0711, P0716, P0717, P0722, or P0723.
- DTC P0711 not passed this key ON.
- Ignition voltage is between 8.6-18.0 volts.
- The ECT is valid.
- The TCM internal temperature is -49°C to +169°C (-56°F and +336°F).
- The engine speed is 500-7500 RPM for at least 5 seconds.
- The vehicle speed is greater than 8 km/h (5 mph) for 300 seconds cumulative.
- The ECT is greater than 70°C (158°F).
- The ECT has increased by 55°C (99°F) since startup.
- The TCM TFT sensor is between 129-170°C (264-338°F) at start up.