Circuit Description
Battery voltage is supplied to the EBD warning lamp with the ignition switch in the ON or START position. The warning lamp can be activated only by the antilock brake system (ABS) control module internally supplying ground to terminal 21.
This procedure checks for a problem in the wiring, a faulty ground, a voltage supply problem, a burned out indicator lamp, or a contact problem in a connector.