Backup Lamps Inoperative
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| 1 |
|
11-14 V | Go to Step 3 | Go to Step 2 |
| 2 | Repair the open circuit between fuse F20 and the backup lamps. Did you complete the repair? |
- | System OK | - |
| 3 | Connect an ohmmeter between ground and the negative terminal at the bulb socket. Is the resistance equal to the specified value? |
0 Ω | Go to Step 4 | Go to Step 5 |
| 4 | Replace the faulty backup lamps. Did you complete the replacement? |
- | System OK | - |
| 5 |
|
11-14 V | Go to Step 7 | Go to Step 6 |
| 6 | Repair the open circuit between the backup lamps and the reverse switch, or the neutral safety/backup switch if equipped with A/T. Did you complete the repair? |
- | System OK | - |
| 7 |
|
0 Ω | Go to Step 9 | Go to Step 8 |
| 8 | Replace the reverse switch, or the neutral safety/backup switch, if equipped with A/T. Did you complete the replacement? |
- | System OK | - |
| 9 | Repair the ground circuit between the reverse switch, or the neutral safety/backup switch, if equipped with A/T, and ground G401. Did you complete the repair? |
- | System OK | - |