Transmission Fluid Cooler Flushing and Flow Test (J 35944-A): Clean-up
WARNING: This page is about a different variant/trim than selected.
- Disconnect the water supply hose from the J 35944-A and bleed any remaining air pressure from the flusher tank. See Special Tools .
- Remove the fill cap from the J 35944-A and return any unused flushing solution to its container. See Special Tools . Rinse the J 35944-A with water. See Special Tools . Do not store theJ 35944-A with flushing solution in it. See Special Tools .
- After every third use, clean the J 35944-A as described in the instructions included with the tool. See Special Tools .
- Dispose of any waste water/solution and transmission fluid in accordance with local regulations.