You must perform the Circuit/System Test before proceeding with the Component Test.
Dynamic Test
- Ignition OFF, install a 3-amp fused jumper wire between the 5-volt reference circuit terminal of the affected APP sensor and 5 volts.
- Install a jumper wire between the low reference circuit terminal and a ground.
- Install a jumper wire at the signal circuit terminal of the affected sensor.
- Ignition ON, sweep the sensor through the entire range while monitoring the voltage between the signal terminal jumper wire and the low reference terminal with a DMM. The voltage should vary between 0.40-4.55 volts without any spikes or dropouts.
- If the voltage is not within the specified range or is erratic, replace the APP sensor assembly.