Fig 1: Measuring Pinion Washer Wear With Feeler Gage
Courtesy of GENERAL MOTORS CORP.
Using a feeler gage, measure the pinion washer wear.
End Play Specification:
The correct end play is between 0.2032-0.6350 mm (0.008-0.025 in).