MALFUNCTIONS Which May Cause a Blinking PRNDL
WARNING: This page is about a different variant/trim than selected.
Failure to detect turbine speed pull-down during a shift may occur under the following conditions:
- A clutch is failed and the transmission cannot attain the requested range.
- Invalid gear ratio
- Pressure control solenoid failure
- Turbine or output speed sensor failure
- Lack of pressure at startup