LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2006 >> Silverado 1500 HD, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1089 (Lighting Systems) >> Diagnostic Information and Procedures >> Courtesy Lamps Malfunction >> Circuit/System Testing >> Vanity Mirror Lamps Malfunction

Vanity Mirror Lamps Malfunction

WARNING: This page is about a different car, the 2008 Cadillac CTS. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the X3 harness connector at the BCM.
  2. Ignition ON, verify that a test lamp illuminates between the BCM 2 fuse voltage supply circuit terminal 2 and ground.
    • If the test lamp does not illuminate, test the voltage supply circuit for a short to ground or an open/high resistance.
  3. Ignition OFF, reconnect the X3 harness connector at the BCM.
  4. Ignition OFF, disconnect the harness connector at the inoperative vanity mirror.
  5. Ignition OFF, scan tool OFF, interior lamps OFF, test for less than 1.0 ohm between the ground circuit terminal B and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  6. Ignition ON, verify that a test lamp illuminates between the courtesy lamp supply voltage circuit terminal A and ground.
    • If the test lamp does not illuminate, test the courtesy lamp supply voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.