Circuit Description

The fuel level sensor changes resistance based on the amount of fuel in the fuel tank. The fuel level sensor has a common, or shared 5-volt reference circuit and a signal circuit. The engine control module (ECM) applies 5 volts on the reference circuit to the sensor. The ECM monitors the changes in this voltage on the signal circuit, caused by a change in the resistance of the fuel level sensor, in order to determine fuel level. The fuel level sensor is part of the fuel sender, and is serviced as an assembly.

When the fuel tank is full, the sensor resistance is low, and the ECM signal voltage is high. When the fuel tank is empty, the sensor resistance is high, and the signal voltage is low.

The ECM uses inputs from the fuel level sensor in order to calculate the total fuel percentage remaining in the fuel tank. The ECM uses the fuel level information for the EVAP and misfire diagnostics. The fuel level information is sent to the instrument panel cluster (IPC).

If the ECM detects a signal voltage higher than the operating range of the sensor, this DTC sets.