Circuit/System Description
The fuel level sensor changes resistance in response to the fuel level. The powertrain control module (PCM) or the engine control module (ECM) monitors the signal circuit of the fuel level sensor in order to determine the fuel level. When the fuel tank is full, the sensor resistance is low and the PCM/ECM senses a low signal voltage. When the fuel tank is empty, the sensor resistance is high and the PCM/ECM senses a high signal voltage. The PCM/ECM uses the signal circuit of the fuel level sensor in order to calculate the percentage of remaining fuel in the tank. The PCM/ECM sends the fuel level percentage via GMLAN serial data circuit to the body control module (BCM). The BCM sends a GMLAN message to the instrument panel cluster (IPC) in order to display the fuel level percent on the fuel gage. The fuel information is also used for misfire and evaporative emission (EVAP) diagnostics.
This diagnostic tests for a stuck fuel level sensor signal. The PCM/ECM sets this DTC if the fuel level sensor signal appears to be stuck based on a lack of signal variation expected during normal operation.