Circuit/System Testing
- Ignition ON, verify the scan tool Engine Oil Pressure Switch parameter is Low.
- If not Low, replace the instrument panel cluster (IPC).
- Ignition OFF, disconnect the EOP switch.
- Ignition ON, engine ON, verify the scan tool Engine Oil Pressure Switch parameter is Ok.
- If Ok, replace the EOP switch.
- If Low, test the signal circuit of the EOP switch for a short to ground. If the circuit tests normal, replace the ECM.