Installation Procedure

WARNING: This page is about a different variant/trim than selected.
    Fig 1: Installing PCV Hose To Outlet Duct
    GM1656106Courtesy of GENERAL MOTORS CORP.
  1. If necessary, install the PCV hose to the outlet duct.
  2. If necessary, position the PCV hose clamp at the outlet duct.
  3. Fig 2: Installing Air Cleaner Outlet Duct To Throttle Body And Air Cleaner Housing
    GM1657019Courtesy of GENERAL MOTORS CORP.
  4. Install the air cleaner outlet duct to the throttle body and air cleaner housing.
  5. NOTE: Refer to Fastener Notice .
  6. Tighten the clamps at the air cleaner housing and throttle body.

    Tighten:  Tighten the clamps to 5 N.m (44 lb in).

  7. Install the push pin retainer.
  8. Install the PCV hose to the camshaft cover.
  9. Position the PCV hose clamp at the camshaft cover.
  10. Fig 3: Connecting Engine Harness Electrical Connector To MAF/IAT Sensor
    GM1647998Courtesy of GENERAL MOTORS CORP.
  11. Connect the engine harness electrical connector to the MAF/IAT sensor.
  12. Install the intake manifold cover. Refer to Intake Manifold Cover Replacement .