Conditions for Setting the DTC

WARNING: This page is about a different variant/trim than selected.

P0340 

The ECM does not receive 4 camshaft pulses within 3 seconds.

P0341 - Near Engine Start, CMP Fast Event Based Test 

The ECM detects the incorrect number of CMP sensor pulses in 2 revolutions of the crankshaft, which is usually within 1 second.

P0341 - After Engine Start, CMP Slow Event Based Test 

The ECM detects the incorrect number of CMP sensor pulses in 2,000 revolutions of the crankshaft, which is usually within 4 minutes.

P0365 

The ECM does not receive 4 camshaft pulses within 3 seconds

P0366 - Near Engine Start, CMP Fast Event Based Test 

The ECM detects the incorrect number of CMP sensor pulses in 2 revolutions of the crankshaft, which is usually within 1 second.

P0366 - After Engine Start, CMP Slow Event Based Test 

The ECM detects the incorrect number of CMP sensor pulses in 2,000 revolutions of the crankshaft, which is usually within 4 minutes.