LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2006 >> Cobalt LTZ >> Repair and Diagnosis >> External Pages >> Different car >> Section 728 (Fixed & MOVEABLE Window Systems) >> Diagnostic Information and Procedures >> Rear Window Defogger Malfunction >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2008 Pontiac G5 and 2008 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.

Rear Window Defogger Switch Malfunction

  1. Ignition OFF, disconnect the X2 harness connector at the HVAC control module.
  2. Test for less than 1 ohm between the ground circuit terminal A5 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify the scan tool Rear Defog Relay Cmd parameter is Off.
    • If not the specified value, test the signal circuit terminal A8 for a short to ground. If the circuit tests normal, replace the BCM.
  4. Install a 3A fused jumper wire between the signal circuit terminal A8 and ground. Verify the scan tool Rear Defog Relay Cmd parameter is On.
    • If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.
  5. If all circuits test normal, test or replace the HVAC control module.

Rear Defogger Malfunction

  1. Ignition OFF, disconnect the REAR DEFOG relay.
  2. Test for less than 1 ohm between the ground circuit terminal 86 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify a test lamp does not illuminate between the control circuit terminal 30 and ground.
    • If the test lamp illuminates, test the control circuit for a short to voltage.
  4. Verify a test lamp illuminates between the B+ circuit terminal 87 and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit 30 for a short to ground.
  5. Ignition OFF, disconnect the X2 harness connector at the rear window defogger grid.
  6. Test for less than 1 ohm between the ground circuit terminal A and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  7. Connect the harness connector at the rear window defogger grid.
  8. Ignition ON, connect a 40A fused jumper wire between the B+ circuit terminal 87 and the control circuit terminal 30. Verify the rear window defogger grid is activated.
    • If the rear window defogger grid does not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the rear window defogger grid.
  9. Connect a test lamp between the control circuit terminal 85 and the ground circuit terminal 86.
  10. Command the Rear Defog Relay ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
    • If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
    • If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
  11. If all circuits test normal, test or replace the REAR DEFOG relay.

Rear Defogger Indicator Malfunction

  1. Ignition OFF, disconnect the X2 harness connector at the HVAC control module.
  2. Disconnect the REAR DEFOG relay.
  3. Connect a test lamp between the control circuit terminal 85 and ground.
  4. Ignition ON, command the Rear Defog Relay ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
    • If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
    • If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
  5. If all circuits test normal, test or replace the HVAC control module.