LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2006 >> Cobalt LTZ >> Repair and Diagnosis >> External Pages >> Different car >> Section 726 (Heating, Ventilation, And Air Conditioning) >> Repair Instructions >> Compressor Hose Assembly Replacement (LNF) >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2008 Pontiac G5 and 2008 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.
    Fig 1: View Of Compressor & Condenser Hose Assembly
    GM865182Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to FASTENER NOTICE .
  1. Install new sealing washers on the compressor and condenser hose fittings. Refer to Sealing Washer Replacement .
  2. Install the A/C compressor and condenser hose assembly to the compressor.
  3. Install the A/C compressor and condenser hose assembly bolt.

    Tighten:  Tighten the bolt to 20 N.m (15 lb ft).

  4. Fig 2: Identifying Compressor Hose Nut & Bracket Bolt
    GM2044556Courtesy of GENERAL MOTORS CORP.
  5. Install new seal washer to the compressor hose. Refer to Sealing Washer Replacement .
  6. Install the compressor hose and nut (1) to the evaporator hose.

    Tighten:  Tighten the nut to 20 N.m (15 lb ft).

  7. Remove the bolt (2) from the compressor hose bracket.

    Tighten:  Tighten the nut to 20 N.m (15 lb ft).

  8. Raise the vehicle. Refer to Lifting and Jacking the Vehicle .
  9. Fig 3: View Of Compressor Hose At Condenser
    GM872545Courtesy of GENERAL MOTORS CORP.
  10. Install new seal washer to the compressor hose. Refer to Sealing Washer Replacement .
  11. Install the compressor hose and bolt to the condenser.

    Tighten:  Tighten the bolt to 20 N.m (15 lb ft).

  12. Fig 4: View Of Pressure Transducer Electrical Connector
    GM872571Courtesy of GENERAL MOTORS CORP.
  13. Connect the pressure transducer electrical connector.
  14. Lower the vehicle.
  15. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging (Non HP2) .
  16. Leak test the fittings using the J 39400-A  . See Special Tools .