Use the Scan Tool Data Display Values and Definitions Information in order to assist in diagnosing the HVAC control assembly problems. Compare the vehicles actual scan tool data with the typical data display value table information. Use the data information in order to aid in understanding the nature of the problem when the vehicle does not match with the typical data display values.

The scan tool data values were taken from a known good vehicle under the following conditions:

Body Control Module (BCM) Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Switch HVAC Data On/Off On
Battery 1 HVAC Data Volts Battery Voltage
Engine Control Module (ECM) Scan Tool Data List (L61, 2.2L)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C High Side Pressure General Info-Inputs kPa/psi Varies
A/C High Side Pressure General Info-Inputs 0 to 5 Volts Varies
A/C Relay Command General Info-Inputs/Outputs On/Off On
A/C Request General Info-Inputs/Outputs Yes/No Yes
ECT All C/F Varies
Engine Control Module (ECM) Scan Tool Data List (LE5, 2.4L)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C High Side Pressure General Info-Inputs kPa/psi Varies
A/C High Side Pressure General Info-Inputs 0 to 5 Volts Varies
A/C Relay Command General Info-Inputs/Outputs On/Off On
A/C Request General Info-Inputs/Outputs Yes/No Yes
ECT All C/F Varies
Powertrain Control Module (PCM) Scan Tool Data List (LSJ, 2.0L)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C High Side Pressure Cooling/HVAC Data kPa/psi Varies
A/C Off For WOT Cooling/HVAC Data Yes/No Varies
A/C Pressure Disable Cooling/HVAC Data Yes/No Varies
A/C Relay Circuit Status Cooling/HVAC Data OK/Fault OK
A/C Relay Command Cooling/HVAC Data On/Off On
A/C Request Signal Cooling/HVAC Data Yes/No Yes
ECT All C/F Varies