Blower Motor Inoperative
WARNING: This page is about a different car, the 2007 Pontiac G5 Pursuit, 2007 Pontiac G5, and 2007 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. |
|||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to DIAGNOSTIC SYSTEM CHECK - VEHICLE |
| 2 |
IMPORTANT:
The mode switch must remain in any position except OFF throughout this diagnostic procedure.
|
Go to Blower Motor Malfunction | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 7 |
| 4 | Connect a test lamp between the blower motor supply voltage circuit and the high blower motor control circuit of the blower motor. Does the test lamp illuminate? |
Go to Step 8 | Go to Step 5 |
| 5 | Test the high blower motor control circuit for an open, short to voltage or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 12 | Go to Step 6 |
| 6 | Test the blower motor switch ground circuit of the HVAC control assembly for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 12 | Go to Step 9 |
| 7 | Repair the blower motor supply voltage circuit. Refer to Circuit Testing
and Wiring Repairs
. Did you complete the repair? |
Go to Step 12 | - |
| 8 | Inspect for poor connections at the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 12 | Go to Step 10 |
| 9 | Inspect for poor connections at the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 12 | Go to Step 11 |
| 10 | Replace the blower motor. Refer to Blower Motor Replacement
. Did you complete the replacement? |
Go to Step 12 | - |
| 11 | Replace the HVAC control assembly. Refer to HVAC Control Assembly Replacement . Did you complete the replacement? |
Go to Step 12 | - |
| 12 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 2 |