Step Action Yes No
Schematic Reference: Exterior Lights Schematics 
Connector End View Reference: Master Electrical Component List
1 Did you perform the Diagnostic System Check - Vehicle? Go to Step 2  Go to DIAGNOSTIC SYSTEM CHECK - VEHICLE
2 Place the hazard switch to the ON position.
Do the hazard lamps turn ON?
Go to Testing for Intermittent Conditions and Poor Connections Go to Step 3 
3
  1. Disconnect the hazard switch.
  2. Install a jumper between the hazard switch signal circuit and the ground circuit.
Do the hazard lamps illuminate?
Go to Step 6  Go to Step 4 
4 Using a test lamp connected to battery positive voltage, probe the ground circuit of the hazard switch.
Does the test lamp illuminate?
Go to Step 5  Go to Step 8 
5 Test the hazard warning switch signal circuit for the following:
  • An open
  • A poor connection
  • A short to battery positive voltage

Refer to Circuit Testing and Wiring Repairs .
Did you find and correct the condition?
Go to Step 11  Go to Step 7 
6 Inspect for poor connections at the hazard switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .
Did you find and correct the condition?
Go to Step 11  Go to Step 9 
7 Inspect for poor connections body control module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .
Did you find and correct the condition?
Go to Step 11  Go to Step 10 
8 Repair a poor connection, an open, or a short to battery positive voltage in the hazard warning switch ground circuit. Refer to Circuit Testing and Wiring Repairs .
Did you complete the repair?
Go to Step 11  -
9 Replace the BCM. Refer to Control Module References for replacement, setup, and programming.
Did you complete the replacement?
Go to Step 11  -
10 Replace the hazard warning switch. Refer to Hazard Warning Switch Replacement .
Is the repair complete?
Go to Step 11  -
11 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 3