LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2005 >> Aveo Base, 4D Hatchback >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating, Ventilation And Air Conditioning >> Repair Instructions >> Refrigerant Recovery and Recharging >> Unsuccessful Transfer

Unsuccessful Transfer

Sometimes the total charge does not transfer into the A/C system. There are 2 reasons why this may occur.

  1. The pressure in the unit's tank and the pressure in the A/C system are roughly equal. This will cause the transfer to proceed too slowly. Refer to the manufacturer's instructions for the charging station in use.
  2. There was not enough refrigerant in the unit's tank to transfer the full charge. It is necessary to recover the partial charge of refrigerant from the vehicle and evacuate and charge the A/C system again. Refer to the manufacturer's instructions for the charging station in use.