Application Description
Nozzle Type Full jet spray nozzle #1/2 GG-25 or equivalent with a 60° included angle
Nozzle Height Approximately 1 600 mm (63 in) from the floor
Volume of Flow 14L (3.7 gal) per minute
Pressure 155 kPa (22.5 psi) measured at the nozzle
Windshield and Windshield Pillar Test Stand Position Approximately 30° down, 45° toward the rear, and aimed at the corner of the windshield
Center Pillar Test Stand Position Approximately 30° down, 45° toward the rear, and aimed at the corner of the rear door
Back Window and Rear Deck Lid Test Stand Position Approximately 30° down, 30° toward the front and aimed approximately 610 mm (24 in) from the corner of the back window