Automatic Transaxle Gear Position Illumination Lamp Inoperative, All Other Instrument Lamps OK
Automatic Transaxle Gear Position Illumination Lamp Inoperative, All Other Instrument Lamps OK
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
|
NOTE:
When probing a bulb socket with a voltmeter or a test lamp, do not allow the probe to touch both the positive and the negative contacts at the same time. This will cause a blown fuse.
|
||||
| 1 | Inspect fuse EF15. Is fuse EF15 open? |
- | Go to Step 2 | Go to Step 3 |
| 2 |
|
- | System OK | - |
| 3 |
|
11-14 V | Go to Step 5 | Go to Step 4 |
| 4 | Repair the open circuit power supply circuit to fuse EF15. Is the repair complete? |
- | System OK | - |
| 5 |
|
11-14 V | Go to Step 7 | Go to Step 6 |
| 6 | Repair the open circuit between the automatic transaxle position lamp socket and fuse EF15. Is the repair complete? |
- | System OK | - |
| 7 |
|
0 Ω | Go to Step 9 | Go to Step 8 |
| 8 | Repair the open ground circuit between the automatic transaxle position lamp socket and ground. Is the repair complete? |
- | System OK | - |
| 9 | Replace the automatic transaxle position lamp. Is the repair complete? |
- | System OK | - |