Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 2: The operating range of the sensor is between 0.1-4.9 volts. If the scan tool displays a value less than 0.1 volt or greater than 4.9 volts, then the sensor is performing outside of its designed limits.
- 3: Tests for the proper operation of the circuit in the high voltage range.
- 4: Tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to voltage.
- 5: Test the signal circuit for a short to ground.
- 6: Tests the signal circuit for a short to voltage, a high resistance, or an open.
- 7: Tests the low reference circuit for a high resistance or an open.
DTC B0158
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics
in HVAC Systems - Manual, Instrument Cluster Schematics or Body Control System Schematics
in Computer/Integrating Systems Connector End View Reference: HVAC Connector End Views |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
|
0.1-4.9 V | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
4.9 V | Go to Step 4 | Go to Step 5 |
| 4 |
|
0.1 V | Go to Step 8 | Go to Step 6 |
| 5 | Test the signal circuit of the outside air temperature sensor for a short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 9 |
| 6 | Test the signal circuit of the outside air temperature sensor for a short to voltage, a high resistance, or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 7 |
| 7 | Test the low reference circuit of the outside air temperature sensor for a high resistance or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 9 |
| 8 | Inspect for poor connections at the harness connector of the outside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 10 |
| 9 | Inspect for poor connections at the harness connector of the BCM. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 11 |
| 10 | Replace the outside air temperature sensor. Refer to the Ambient Air Temperature Sensor Replacement
in Stationary Windows. Did you complete the replacement? |
- | Go to Step 12 | - |
| 11 |
IMPORTANT:
Perform the recalibration procedure for the body control module after the replacement procedure. Replace the BCM. Refer to Control Module References
in Computer/Integrating Systems for replacement, setup, and programming.Did you complete the replacement? |
- | Go to Step 12 | - |
| 12 |
|
- | Go to Step 2 | System OK |