Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- If necessary, install and connect the CVS line. Refer to Quick Connect Fitting(s) Service (Plastic Collar) .
- Install the CVS and line.
- Engage the retaining tab on the CVS bracket (2).
- Connect the CVS quick connect fittings at the canister. Refer to Quick Connect Fitting(s) Service (Plastic Collar) .
- Connect the EVAP canister vent solenoid (CVS) electrical connector (1).
- Lower the vehicle.