Fuel Gage
The IPC displays the fuel level as determined by the PCM. The body control module (BCM) receives a class 2 message from the PCM indicating the fuel level percent. The BCM converts the fuel level percent into a percent gage deflection. The IPC receives a message from the BCM via the serial peripheral interface (SPI) indicating the requested gage position.
The fuel gage defaults to E (empty) if:
- The PCM detects a malfunction in the fuel level sensor circuit.
- The BCM detects a loss of class 2 communications with the PCM.
- The IPC detects a loss of SPI communications with the BCM.
When the fuel level is less than a pre-determined value, the low fuel indicator illuminates.