Fuel Gage Inaccurate or Inoperative
Fuel Gage Inaccurate or Inoperative
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| 1 | Did you review the Instrument Panel Cluster (IPC) Description and Operation and perform the necessary inspections? | - | Go to Step 2 | Go to Symptoms - Instrument Panel, Gages and Console |
| 2 | Verify that the fuel gage is inoperative. Does the fuel gage operate normally? |
- | Go to TESTING FOR INTERMITTENT AND POOR CONNECTIONS | Go to Step 3 |
| 3 |
|
Full-0 ohms 3/4-15 ohms 1/2-35 ohms 1/4-60 ohms Empty-100 ohms |
Go to Step 4 | Go to Step 6 |
| 4 | Test for an open or high resistance in the BLK/YEL wire between the fuel level sensor and G203. Does an open or high resistance condition exist? |
- | Go to Step 5 | Go to Step 7 |
| 5 | Repair the open or high resistance in the BLK/YEL wire between the fuel level sensor and G400. Did you complete the repair? |
- | Go to Step 10 | - |
| 6 | Replace the fuel gage. Refer to Instrument Panel Cluster (IPC) Replacement . Did you complete the repair? |
- | Go to Step 10 | - |
| 7 | Test for an open or high resistance condition in the BLU/WHT wire between instrument panel cluster connector C3 and the fuel level sensor. Does an open or high resistance condition exist? |
- | Go to Step 8 | Go to Step 9 |
| 8 | Repair the BLU/WHT wire between the instrument panel cluster assembly and the fuel level sensor. Did you complete the repair? |
- | Go to Step 10 | - |
| 9 | Replace the Fuel level sending unit. Refer toFuel Sender Assembly Replacement
. Did you complete the replacement? |
- | Go to Step 10 | - |
| 10 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 3 |