Gages Inoperative - All
Gages Inoperative - All
| Step | Action | Yes | No |
|---|---|---|---|
| 1 | Did you review the Instrument Panel Cluster (IPC) Description and Operation and perform the necessary inspections? | Go to Step 2 | Go toSymptoms - Instrument Panel, Gages and Console |
| 2 | Verify that the instrument cluster gages are inoperative. Do the gages operate normally? |
Go toTESTING FOR INTERMITTENT AND POOR CONNECTIONS | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 5 |
| 4 | Repair the open in the BLK/WHT wire between the instrument cluster and the junction block C4 cavity 1. Did you complete the repair? |
Go to Step 9 | - |
| 5 |
|
Go to Step 6 | Go to Step 7 |
| 6 | Repair the short in the BLK/YEL wire between the instrument cluster and G103. Did you complete the repair? |
Go to Step 9 | - |
| 7 | Inspect the instrument cluster for any damage to the cluster or printed circuit. Is there any damage to the instrument cluster or printed circuit? |
Go to Step 8 | Go to TESTING FOR INTERMITTENT AND POOR CONNECTIONS |
| 8 | Repair or replace the instrument cluster or printed circuit. Did you complete the repair? |
Go to Step 9 | - |
| 9 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |