LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 976 (Engine Controls - 6.6L (Lb7) (Introduction)) >> Repair Instructions >> Air Cleaner Outlet Duct Replacement >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2004 GMC Sierra, 2004 GMC Cab & Chassis Sierra, 2004 Chevrolet Silverado, and 2004 Chevrolet Cab & Chassis Silverado. However, it is still accessible from the selected car via links, so may be relevant.
    IMPORTANT: The outlet duct must be fully seated against the positive stop feature on the turbocharger inlet.
  1. Install the outlet duct to the turbocharger.
  2. Align the outlet duct alignment indicator (1) to the turbocharger alignment indicator (2).
  3. Fig 1: Outlet Duct Alignment Indicator & Turbocharger Alignment Indicator
    GM813246Courtesy of GENERAL MOTORS CORP.
  4. Install the outlet duct to the MAF/IAT sensor.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
  5. Tighten the outlet duct clamps at the turbocharger and the MAF/IAT sensor.

    Tighten:  Tighten the clamp to 6 N.m (53 lb in).

  6. Fig 2: View Of Outlet Duct
    GM813244Courtesy of GENERAL MOTORS CORP.
  7. Install the upper intake manifold cover.
  8. Install the upper intake manifold cover to the outlet duct.
  9. Tighten the outlet duct clamp at the upper intake manifold cover.

    Tighten:  Tighten the clamp to 6 N.m (53 lb in).

  10. Fig 3: View Of Upper Intake Manifold Cover, Outlet Duct & Clamp
    GM813243Courtesy of GENERAL MOTORS CORP.