Circuit Description
WARNING: This page is about a different car, the 2003 GMC Yukon XL, 2003 Chevrolet Suburban, and 2003 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
The 2-3 shift solenoid (SS) valve controls fluid flow of the 2-3 shift valves. The 2-3 SS valve is a normally-open exhaust valve used with the 1-2 SS valve in order to allow for four different shift combinations.
When the powertrain control module (PCM) detects a 4-3-3-4 gear ratio, then DTC P0756 sets. DTC P0756 is a type C DTC. For California emissions vehicles and vehicles under 8,600 GVW, DTC P0756 is a type A DTC.