Scan Tool Data List
WARNING: This page is about a different car, the 2002 Oldsmobile Bravada, 2002 GMC Envoy XL, 2002 GMC Envoy, and 2002 Chevrolet TrailBlazer. However, it is still accessible from the selected car via links, so may be relevant.
HVAC Control Module Scan Tool Data List
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
| A/C Head Pressure | A/C Permission | Yes, No | No |
| A/C Switch | Input/Output | On, Off | Off |
| AC Compressor Feedback | Input/Output | On, Off | Varies |
| AC Permission | Input/Output | Withheld, Granted | Varies |
| AC/Heater Door Actual | Door Positions | Counts | Varies |
| AC/Heater Door Commanded | Door Positions | Counts | Varies |
| AC/Heater Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
| Air Mix Door Left Commanded | Door Positions | Counts | Varies |
| Air Mix Door Right Commanded | Door Positions | Counts | Varies |
| Battery Voltage | Input/Output | Volts | 13.5-14.5 V |
| Blower Motor Status | Input/Output | Active/Inactive | Active |
| Blower Speed | A/C Permission | Yes, No | No |
| Defrost Door Actual | Door Positions | Counts | Varies |
| Defrost Door Commanded | Door Positions | Counts | Varies |
| Defrost Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
| Engine Coolant Temp | A/C Permission | Yes, No | No |
| Engine Running | A/C Permission | Yes, No | No |
| Ign. Since Current DTC | Input/Output | Numeric | 0 |
| Left Mix Door Actual | Door Positions | Counts | Varies |
| Left Mix Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
| Left Temp. Detent Pos. | Input/Output | 0-18 | Hot 18/Cold 0 |
| Mode Select Position | Door Positions | Off, Defrost, Heater, Htr/Def, Bi-level, Panel | Varies |
| Outside Air Temp | A/C Permission | Yes, No | No |
| Pressure Cycle Switch | A/C Permission | Yes, No | No |
| Pressure Cycle Switch | Input/Output | Low Pressure, Normal | Varies |
| Recirculate Switch | Input/Output | On, Off | Off |
| Right Mix Door Actual | Door Positions | Counts | Varies |
| Right Mix Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
| Right Temp. Detent Pos. | Input/Output | 0-18 | Hot 18/Cold 0 |
Rear HVAC Control Module Scan Tool Data List
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
| Air Mix Door Actual | Door Positions | Counts | Varies |
| Air Mix Door Commanded | Door Positions | Counts | Varies |
| Battery Voltage | Input/Output | Volts | 13.5-14.5 V |
| Console Mode Door Actual | Door Positions | Counts | 0.0 Volts |
| Console Mode Door Commanded | Door Positions | Counts | Varies |
| Driver Override Switch | Input/Output | Rear, Off, Low, Med, High | Varies |
| Heater Water Valve | Input/Output | Open, Closed | Closed |
| Ign. Since Current DTC | Input/Output | Cycles | Varies |
| Mode Door Actual | Door Positions | Counts | Varies |
| Mode Door Commanded | Door Positions | Counts | Varies |
| Rear Blower Speed | Input/Output | Off, Low, Med, High | Varies |
| Rear HVAC Fan Speed | Input/Output | Off, Low, Med, High | Varies |
| Rear HVAC Motor Pos. | Door Positions | Lower, Bi-level, Upper | Bi-level |
| Rear Temp. Select Sw. | Input/Output | Counts | Varies |
| Rec. Mode from Front Control | Door Positions | Heater, Panel, Defrost, Bi-level, Htr./Def. | Varies |
PCM Scan Tool Data List
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
| A/C High Side Pressure | Engine Data 2 | kPa, psi | 629-845 kPa (85-120 psi) |
| A/C High Side Pressure | Engine Data 2 | Volts | Varies |
| A/C Relay Command | Engine Data 2 | On, Off | Varies |
| A/C Request Signal | Engine Data 2 | Yes, No | Varies |
| ECT Sensor | Engine Data 2 | °C/°F | 92°C (197°F) |