Cleaning Procedure
WARNING: This page is about a different car, the 2003 Pontiac Grand Prix, 2003 Chevrolet Malibu, and 2003 Buick Century. However, it is still accessible from the selected car via links, so may be relevant.
- Raise and support the vehicle.
- Remove the EVAP canister.
- Turn OFF the main valve on the EVAP Pressure/Purge Diagnostic Station.
- Disconnect the hose from the diagnostic station pressure regulator.
- Using a section of vacuum hose, connect one end onto the diagnostic station pressure regulator.
- Connect the other end of the vacuum hose to the canister side of the purge pipe.
- Turn ON the main nitrogen cylinder valve and continue to discharge nitrogen for 15 seconds.
- If the nitrogen does not dislodge the carbon particles, replace the purge pipe.
- Return the EVAP pressure/purge diagnostic station to the original condition of the station.
- Install a new EVAP canister.
- Lower the vehicle.
- Install a new EVAP canister purge valve.
- Return to the diagnostic procedure that sent you here.