Checking Fluid Levels
WARNING: This page is about a different car, the 2003 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:
Saturn ATF (P/N 21005966 and 21019223), and DEXRON-III ATF are not compatible with this transaxle. This transaxle uses Saturn DEX-CVT(R) Fluid (P/N 22688912) only.
NOTE:
The VT25E transaxle is not equipped with a dipstick.
- Install scan tool. Start vehicle. Perform the following:
- Shift transaxle from Park to Reverse for 10 seconds.
- Shift transaxle from Reverse to Drive for 10 seconds.
- Shift transaxle back to Park. The engine should remain running.
- Remove the plug from the center of the fluid fill lower tube. The fluid fill lower tube is located on the bottom of the unit. See Fig 1 .
- If fluid drains down as a steady stream from the opening, wait for it to stop. If fluid does not drain from the opening, add more fluid until it starts to drain as a steady stream, then stop adding fluid immediately. Allow fluid to drain until the fluid stream stops.
- Replace the lower fill tube plug. Tighten the plug to specification. See TORQUE SPECIFICATIONS
.NOTE: DO NOT remove the plug.
- On the scan tool, observe the Trans. Fluid Temp. and record the temperature.
- If TRANS FLUID TEMP is 68°F (20°C), add 0.5 Qt. (0.47L) of fluid to the transaxle.
- If TRANS FLUID TEMP is 104°F (40°C), add 0.75 Qt. (0.71L) of fluid to the transaxle.
- If TRANS FLUID TEMP is 140°F (60°C), add 1.0 Qt. (0.95L) of fluid to the transaxle.
- If TRANS FLUID TEMP is 176°F (80°C), add 1.25 Qts. (1.2L) of fluid to the transaxle.