Diagnostic Aids
WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
P0451
- A restriction in the EVAP canister or vent lines could prevent fuel vapor pressure from bleeding off fast enough. If the vent system cannot bleed off pressure fast enough, the re-zero procedure may not complete successfully, which could cause this code to set. By using the Purge Solenoid command on a scan tool, vacuum can be applied to the system instead of pressure. With the EVAP canister vent solenoid valve open and the EVAP canister purge solenoid valve commanded to 100 percent, the vacuum should not increase to more than 9 inches H2O.
- Ensure that the reference port on the FTP sensor is unobstructed.
P0454
- This diagnostic is designed to detect an unexpected abrupt voltage signal change from the FTP.
- Scan tool output controls, snapshot, and plot functions can help detect erratic sensor response. To look at the sensor signal under vacuum conditions, use Snapshot and the Purge/Seal function to capture data while commanding purge to 30 percent, then plot the data to look for erratic sensor operation. A similar inspection can be done for the pressure side of the sensor range by applying pressure with the J 41413-200 while taking a snapshot.
- Ensure that the reference port on the FTP sensor is unobstructed.