Conditions for Running the DTC
WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
P0030 and P0036
- The engine is cranking or running.
- The Engine Speed parameter is greater than 400 RPM.
- The system voltage is between 10-18 volts.
P0053 and P0054
- DTCs P0112, P0113, P0116, P0117, P0118, P0128, P1258, P2610 are not set.
- The ignition is OFF for more than 10 hours.
- The difference between the start-up engine coolant temperature (ECT) and the intake air temperature (IAT) is less than 8°C (14.4°F).
- The ECT Sensor parameter is between -30 and +45°C (-22 and +133°F) at engine start-up.
- The system voltage is between 10-18 volts.
- This diagnostic runs one time per valid cold start when the above conditions are met.
P0135
- DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453, P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176, are not set.
- The system voltage is between 10-18 volts.
- The scan tool special functions are not active.
- The Engine Run Time parameter is more than 180 seconds.
- The ECT Sensor parameter is at least 65°C (149°F).
- The Engine Speed parameter is between 500-3,000 RPM.
- The MAF Sensor parameter is between 5-30 g/s.
- The above conditions have been met for more than 2 seconds.
P0141
- DTCs P0036, P0054, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453, P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set.
- The system voltage is between 10-18 volts.
- The scan tool special functions are not active.
- The Engine Run Time parameter is at least 180 seconds.
- The ECT parameter is at least 65°C (149°F).
- The Engine Speed parameter is between 500-3,000 RPM.
- The MAF Sensor parameter is between 5-30 g/s.
- The above conditions have been met for more than 2 seconds.