LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 1967 (Hybrid Energy Storage System - 2.4L (Hp7)) >> Diagnostic Information and Procedures >> DTC P1A26 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
WARNING: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
NOTE: In order to avoid damaging BECM X1 and X2 connector terminals, the proper test probes should be used. The proper test probes are as follows:
  1. Gain access to the battery pack. Refer to Hybrid Battery Service Disconnect/Connect .
  2. Measure voltage across the battery pack modules. The voltage should be greater than 22 volts.
    • If less than specified value, replace the battery pack.
  3. Disconnect BECM connector X1.
  4. Test for 1.3-1.7k ohms between the following circuits:
    • X1 terminal 12 and Generator Battery 3- X2
    • X1 terminal 2 and Generator Battery 2- X2
    • X1 terminal 11 and Generator Battery 1- X2
    • X1 terminal 1 and Generator Battery 1- X1
    • If not within specified range, replace the voltage sensor harness assembly.
  5. If all circuits test normal, replace the BECM.