Circuit/System Testing
WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Sun Load Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the sunload sensor.
- Test for less than 10 ohms between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, test for 4.8-5.2 volts between the ground circuit terminal C and the appropriate signal circuit terminal listed below:
- Left solar load sensor circuit terminal A
- Right solar load sensor circuit terminal B
- If less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the sunload sensor.
Ambient Air Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the ambient air temperature sensor.
- Ignition OFF, test for less than 10 ohms between the following low reference circuit terminal B and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the scan tool Outside Air Temp. Raw parameter is less than -35°C (-39°F).
- If greater than the specified range, test the following signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3A fused jumper wire between the following signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Outside Air Temp. Raw parameter is greater than 85°C (185°F).
- If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the ambient air temperature sensor.
Inside Air Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the inside air temperature sensor.
- Test for less than 1 ohm between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify a test lamp illuminates between the control circuit terminal B and ground.
- If the test lamp does not illuminate, test the ground circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition OFF, test for less than 10 ohms between the low reference circuit terminal D and ground:
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify that the scan tool Inside Air Temp. Sensor parameter is less than -35°C (-39°F).
- If greater than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3A fused jumper wire between the signal circuit terminal A and the low reference circuit terminal D. Verify the scan tool Inside Air Temp. Sensor is greater than 98°C (208°F).
- If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the inside air temperature sensor.
Duct Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate duct temperature sensor.
- Ignition OFF, test for less than 10 ohms between the low reference circuit terminal 2 listed below and ground:
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify that the appropriate scan tool Duct Actual parameter is less than -35°C (-39°F).
- If greater than the specified range, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3A fused jumper wire between the signal circuit terminal 1 and the low reference circuit terminal 2. Verify the appropriate scan tool Duct Actual parameter is greater than 98°C (208°F).
- If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the appropriate duct temperature sensor.
Heater Core Coolant Pump Malfunction
- Ignition OFF, disconnect the harness connector at the heater core coolant pump.
- Ignition ON, verify that a test lamp illuminates between the control circuit terminal B and ground while commanding the pump ON and OFF with a scan tool.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the SGCM.
- Verify that a test lamp illuminates between the B+ circuit terminal A and ground.
- If the test lamp does not light, test the B+ circuit for a short to ground, open or high resistance. If the circuit tests normal, replace the Coolant heater pump