Circuit/System Testing

WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
  • Identify how to disable high voltage.
  • Identify how to test for the presence of high voltage.
  • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.

Failure to follow the procedures exactly as written may result in serious injury or death.
  1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling .
  2. Disconnect the X4 harness connector at the drive motor battery disconnect control module.
  3. Ignition OFF, test for less than 5 Ω between the low reference circuit terminal 6 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the drive motor generator battery control module.
  4. Connect the 12 V battery.
  5. Ignition ON, test for 4.8-5.2 V between the 5 V reference circuit terminal 3 and ground.
    • If less than the specified range, test the 5 V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the drive motor generator battery control module.
    • If greater than the specified range, test the 5 V reference circuit for a short to voltage. If the circuit tests normal, replace the drive motor generator battery control module.
  6. Install a 3 A fused jumper wire between the signal circuit terminal 4 and the 5 V reference circuit terminal 3. Verify the scan tool Calc. Hybrid Battery Current parameter is greater then -200 A.
    • If not within the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the drive motor generator battery control module.
  7. If all circuits test normal, replace the drive motor battery disconnect control module.