Circuit/System Description
The primary fuel level sender and the secondary fuel level sender changes resistance based on fuel level. The engine control module (ECM) monitors the signal circuits of the primary fuel level sender and the secondary fuel level sender in order to determine the fuel level. When the fuel tank is full, the resistances of both fuel level senders are low and the ECM senses a low signal voltage on both the signal circuits of the primary fuel level sender and the secondary fuel level sender. When the fuel tanks are empty, the resistances of the fuel level senders are high and the ECM senses a high signal voltage. The ECM uses the signal circuits of the primary fuel level sender and the secondary fuel level sender in order to calculate the percentage of remaining fuel in the tank. The ECM sends the fuel level percentage via serial data circuit to the instrument cluster in order to control the fuel gage.