Test Description
WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 1: This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
- 2: This step measures the performance of the A/C system.
- 3: This step is to allow for vehicle variations as well as high ambient temperatures.
Air Conditioning (A/C) System Performance Test (L61)
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
|
IMPORTANT:
|
||||
| 1 |
|
More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) |
Go to Step 2 | Go to Leak Testing |
| 2 |
IMPORTANT:
Record the relative humidity and the ambient air temperature at the time of the test.
IMPORTANT:
Press the RESET button, before using the print function of the J 43600
. See Special Tools .
|
- | Go to Step 8 | Go to Step 3 |
| 3 | If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C Performance Table? |
- | Go to Step 8 | Go to Step 4 |
| 4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A | Go to Step 5 |
| 5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B | Go to Step 6 |
| 6 | Are the low and high side pressures both greater than the specified ranges? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C | Go to Step 7 |
| 7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D | Go to Step 8 |
| 8 | Operate the system in order to verify the test results. Did you find the same results? |
- | System OK | Go to Symptoms - HVAC Systems - Manual |
A/C Performance Table
| Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
|---|---|---|---|---|
| 13-18°C (55-65°F) | 0-100% | 151-241 kPa (22-35 psi) | 861-1136 kPa (125-165 psi) | 9°C (48°F) |
| 19-24°C (66-75°F) | Less than 40% | 151-261 kPa (22-38 psi) | 999-1309 kPa (145-190 psi) | 10°C (50°F) |
| Greater than 40% | 165-296 kPa (24-43 psi) | 1026-1350 kPa (149-196 psi) | 13°C (55°F) | |
| 25-29°C (76-85°F) | Less than 35% | 199-296 kPa (29-43 psi) | 1198-1467 kPa (174-213 psi) | 13°C (55°F) |
| 35-50% | 213-310 kPa (31-45 psi) | 1219-1488 kPa (177-216 psi) | 14°C (57°F) | |
| Greater than 50% | 227-330 kPa (33-48 psi) | 1240-1529 kPa (180-222 psi) | 17°C (61°F) | |
| 30-35°C (86-95°F) | Less than 30% | 241-351 kPa (35-51 psi) | 1357-1660 kPa (197-241 psi) | 18°C (63°F) |
| 30-50% | 254-358 kPa (37-52 psi) | 1378-1701 kPa (200-247 psi) | 18°C (64°F) | |
| Greater than 50% | 268-378 kPa (39-55 psi) | 1412-1750 kPa (205-254 psi) | 20°C (68°F) | |
| 36-41°C (96-105°F) | Less than 20% | 296-399 kPa (43-58 psi) | 1543-1832 kPa (224-266 psi) | 22°C (70°F) |
| 20-40% | 303-406 kPa (44-59 psi) | 1557-1880 kPa (226-273 psi) | 23°C (72°F) | |
| Greater than 40% | 316-413 kPa (46-60 psi) | 1598-1922 kPa (232-279 psi) | 23°C (73°F) | |
| 42-46°C (106-115°F) | Less than 20% | 351-447 kPa (51-65 psi) | 1729-1998 kPa (251-290 psi) | 24°C (75°F) |
| Greater than 20% | 358-447 kPa (52-65 psi) | 1750-2053 kPa (254-298 psi) | 25°C (77°F) | |
| 47-49°C (116-120°F) | Below 30% | 406-496 kPa (59-72 psi) | 1922-2259 kPa (279-328 psi) | 28°C (82°F) |