Circuit Description
WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
The 4-3 downshift solenoid valve controls transmission fluid pressure acting on the shift timing valve to position the valves for the appropriate gear. The 4-3 downshift solenoid valve is a normally closed exhaust valve located on the channel plate. Ignition voltage is supplied to the solenoid. The transmission control module (TCM) commands the solenoid ON or OFF by providing a ground path. When the 43 downshift solenoid valve is commanded ON, the TCM senses low voltage. When the 4-3 downshift solenoid valve is commanded OFF, the TCM senses high voltage.
If the TCM detects a continuous short to voltage in the 4-3 downshift solenoid valve circuit, then DTC P0788 sets. DTC P0788 is a type C DTC.