Circuit/System Testing
WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
- If DTC P0454 is set, inspect for an intermittent and for a poor connection at the FTP sensor.
- Ignition OFF, remove the fuel tank filler cap.
- Connect the GE-41415-50 to the fuel fill pipe. Connect the J 41413-200 to the J 41415-40 . Install the fuel tank filler cap to the GE-41415-50 .
- Ignition ON, engine OFF, seal the EVAP system with a scan tool.
- Turn the nitrogen/smoke valve on the J 41413-200 to nitrogen. Use the remote switch to pressurize the fuel tank with nitrogen to 10 inch H20.
- Compare the scan tool FTP sensor parameter to the J 41413-200
pressure/vacuum gage. The scan tool FTP sensor parameter should be within 1 inch H20 of the pressure/vacuum gage.
- If not within the specified range, replace the FTP sensor.
- With a scan tool command the vent solenoid valve OPEN. The scan tool FTP sensor parameter should read 0 inch H20.
- If not within the specified range, replace the FTP sensor.
IMPORTANT:
DO NOT exceed the specified value in this step. Exceeding the specified value may produce incorrect test results.