Circuit Description
The shift solenoid (SS) valve 2 is mounted to the transmission case and is used to supply or limit the modulated pressure to the shift valve B, according to the PCM command. The powertrain control module (PCM) provides an output signal to SS valve 2, which supplies clutch control pressure to the clutch of an appropriate gear position, as determined by the shift schedule. When the PCM commands the shift solenoid 2 ON, the modulated pressure is not supplied to the shift valve B, and the shift valve B is pushed by the reactive force of spring B. When the PCM command is OFF, the modulated pressure is supplied to the valve. The PCM monitors mainshaft to output shaft speed ratio in the gear positions determined by the shift schedule.
When the PCM detects an incorrect ratio for the commanded gear, DTC P0757 sets. DTC P0757 is a type B DTC.
Refer to Shift Solenoid Valve State and Gear Ratio .