Circuit Description
The shift solenoid (SS) valve 1 is mounted to the transmission case and is used to supply or cut off the modulated pressure to the shift valve A, according to the powertrain control module (PCM) command. The signal from the PCM is output, so that a clutch control pressure is supplied to the clutch of an appropriate gear position, as determined by the shift schedule. When the PCM command to the shift solenoid valve 1 is ON, the modulated pressure is not supplied to the shift valve A, and the shift valve A is pushed by the reactive force of spring A. When the PCM command is OFF, the modulated pressure is supplied to the valve. The PCM monitors mainshaft to output shaft speed ratio in the gear positions determined by the shift schedule.
When the PCM detects an incorrect ratio for the commanded gear, DTC P0752 is set. DTC P0752 is a type B DTC.
Refer to Shift Solenoid Valve State and Gear Ratio .