P0A06

  1. Ignition OFF, disconnect the harness connector at the SGCM coolant pump.
  2. Ignition ON, verify that a test lamp illuminates between the control circuit terminal 1 and ground.
    • If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the SGCM.

P0A07

  1. Ignition OFF, disconnect the harness connector at the SGCM coolant pump.
  2. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 2 and control circuit terminal 1.