Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 1819 (Engine Mechanical - 3.5L (L66)) >> Repair Instructions >> Off Vehicle Repair Instructions >> Crankshaft and Bearings Cleaning and Inspection >> Crankshaft Main Bearing Clearance Measurement

Crankshaft Main Bearing Clearance Measurement

WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
    Fig 1: View Of Crankshaft Main Bearings & Caps
    GM897010Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: If the bearing clearance measurement procedure is to performed in-vehicle, the crankshaft must be supported upward with a jack. The weight of the crankshaft and drive plate will flatten the plastic gaging material and contribute to an inaccurate measurement.
  1. Remove the bolts (108 and 109) caps (103) and lower bearings (106). Refer to Crankshaft and Bearings Removal .
  2. Clean each main journal and bearing half with a clean shop towel.
  3. Place 1 strip of plastic gaging material across each main journal.
  4. Install the bearings, caps and bolts. Refer to Crankshaft and Bearings Installation .
  5. Remove the bolts, bearing caps and bearings. Refer to Crankshaft and Bearings Removal .
  6. Fig 2: Measuring The Widest Part Of The Plastic Gaging Material
    GM897394Courtesy of GENERAL MOTORS CORP.
  7. Measure the widest part of the plastic gaging material (1).
  8. If the measurement is too wide or too narrow, remove the crankshaft and the bearing upper half. Install a new bearing assembly of the same color and measure again. Do not file, shim or scrape the bearings or caps to adjust the clearance.
  9. If the plastic gaging measurement is still incorrect, try the next larger or smaller bearing. If the correct clearances cannot be obtained, replace the crankshaft assembly.

    Specification: 

    • Main bearing-to-journal clearance - new: 0.02-0.044 mm (0.0008-0.0017 in)
    • Main bearing-to-journal clearance - service limit: 0.05 mm (0.002 in)