Defrosting Insufficient
WARNING: This page is about a different car, the 2003 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Defrosting Insufficient
| Step | Action | Yes | No |
|---|---|---|---|
| DEFINITION: Time required to defrost the windshield is longer than usual. | |||
| 1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual |
| 2 |
|
Go to Step 3 | Go to Step 11 |
| 3 | Measure the engine operating temperature. Does engine reach normal operating temperature? |
Go to Step 4 | Go to Step 9 |
| 4 |
|
Go to Step 12 | Go to Step 5 |
| 5 | Is the vehicle equipped with air conditioning? | Go to Step 6 | Go to Step 14 |
| 6 | Test the operation of the A/C compressor clutch. Does the A/C compressor clutch engage? |
Go to Step 8 | Go to Step 7 |
| 7 | Repair the A/C compressor clutch. Refer to HVAC Compressor Clutch Does Not Engage
in HVAC Systems - Manual. Is the repair complete? |
Go to Step 15 | - |
| 8 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test . Is the A/C system operating within the specifications? |
Go to Step 10 | Go to Step 13 |
| 9 | Repair the low engine temperature concern. Refer to Engine Fails To Reach Normal Operating Temperature
in Engine Cooling. Is the repair complete? |
Go to Step 15 | - |
| 10 | Inspect for correct operation of the recirculation door. Is the recirculation door operating correctly? |
Go to Step 15 | Go to Step 14 |
| 11 | Repair the air delivery concern. Refer to Air Delivery Improper
in HVAC Systems - Manual. Is the repair complete? |
Go to Step 15 | - |
| 12 | Repair the heating concern. Refer to Heating Performance Diagnostic . Is the repair complete? |
Go to Step 15 | - |
| 13 | Repair the A/C performance concern. Refer to Air Conditioning (A/C) System Performance Test . Is the repair complete? |
Go to Step 15 | - |
| 14 | Repair the recirculation door concern. Refer to Air Recirculation Malfunction
in HVAC Systems - Manual. Is the repair complete? |
Go to Step 15 | - |
| 15 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Step 2 |