Door Ajar Indicator Malfunction
WARNING: This page is about a different car, the 2003 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Door Ajar Indicator Malfunction
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Door Lock/Indicator Schematics Connector End View Reference: Power Door Systems Connector End Views |
|||
| 1 | Did you perform the Door Systems Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Door Systems |
| 2 | Open and close the driver and passenger doors one at a time while monitoring the driver information center (DIC) display. Do the door ajar indicators operate properly? |
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 | Do the dome lamps operate properly with the opening and closing of each of the doors? | Go to Step 4 | Go to Symptoms - Lighting Systems in Lighting Systems |
| 4 |
IMPORTANT:
Perform the setup procedure for the instrument panel cluster. Replace the instrument panel cluster. Refer to Instrument Panel Cluster (IPC) Replacement
in Instrument Panel, Gages and Console.Did you complete the replacement? |
Go to Step 5 | - |
| 5 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |