Test Description
WARNING: This page is about a different car, the 2003 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
The number below refers to the step number on the diagnostic table.
- 6: The HVAC control assembly is supplied by 2 ignition-3 voltage circuits. Test both ignition-3 voltage circuits.
- 9: Check the connection by removing and securely reinstalling before replacement of the control HEAD is considered.
Air Recirculation Malfunction
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. |
|||
| 1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Manual |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
Go to Step 5 | Go to Step 4 |
| 4 | Test the recirculation door control A and B circuits of the recirculation actuator for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 12 | Go to Step 6 |
| 5 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? |
Go to Step 12 | Go to Step 8 |
| 6 | Test the ignition 3 voltage circuits of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 12 | Go to Step 7 |
| 7 | Test the ground circuit of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 12 | Go to Step 9 |
| 8 | Inspect for bad connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 12 | Go to Step 10 |
| 9 | Inspect for bad connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 12 | Go to Step 11 |
| 10 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? |
Go to Step 12 | - |
| 11 | Replace the HVAC Control assembly. Refer to HVAC Control Module Replacement . Did you complete the replacement? |
Go to Step 12 | - |
| 12 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |