Test Description
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2002 GMC Yukon XL, 2002 GMC Yukon, 2002 Chevrolet Tahoe, 2002 Chevrolet Suburban, and 2002 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to thew step numbers on the diagnostic table.
- 2: This step ensures that the primary HVAC system is functioning properly.
- 3: The DTC's listed could set if a calibration of the actuators is performed.
- 6: If the condition does not occur when an A/C request has been made then you must bypass the A/C performance test procedures.
- 7: Performing the Air Conditioning System Performance Test ensures that the A/C system is operating properly for further testing.
- 8: This step ensures that the rear auxiliary HVAC control module is able to move the auxiliary air temperature actuator.
- 9: This step ensures that the front auxiliary HVAC control assembly is able to move the auxiliary air temperature actuator.
- 11: The infrared sensor is located between the auxiliary blower motor switch and the auxiliary temperature switch on rear auxiliary HVAC control module. It has a glass cover protecting the sensor which is integral to the rear auxiliary HVAC control module.
Too Hot in Vehicle - Auxiliary (w/o Sunroof)
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics DEFINITION: Auxiliary air temperature can not be adjusted from one or both auxiliary controls or auxiliary cooling is insufficient. |
||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 | The auxiliary HVAC control assembly cannot request A/C compressor operation. An A/C request must be generated by the HVAC control module to provide cooled airflow through the auxiliary system. Does the HVAC control module operate and provide sufficient cooling? |
- | Go to Step 3 | Go to Too Hot in Vehicle |
| 3 |
IMPORTANT:
If during this diagnostic procedure the HVAC control module is disconnected a recalibration of actuators must be performed to avoid misdiagnosis.
|
- | Go to Diagnostic Trouble Code (DTC) List | Go to Step 4 |
| 4 |
|
- | Go to Step 5 | Go to Blower Motor Inoperative - Auxiliary (W/O Sunroof) Blower Motor Inoperative - Auxiliary (W/Sunroof or Heat Only) |
| 5 | Does the auxiliary blower motor operate at the desired speed in each speed position? | - | Go to Step 6 | Go to Blower Motor Malfunction - Auxiliary (W/O Sunroof) Blower Motor Malfunction - Auxiliary (W/Sunroof or Heat Only) |
| 6 | Does the Auxiliary Too Hot In Vehicle concern occur when A/C cooling is desired? | - | Go to Step 7 | Go to Step 8 |
| 7 | Perform the refrigerant system performance test. Refer to A/C SYSTEM PERFORMANCE TEST
. Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 8 |
| 8 |
|
- | Go to Step 9 | Go to Step 13 |
| 9 |
|
- | Go to Step 10 | Go to Step 14 |
| 10 | Check the auxiliary upper outlet and auxiliary lower outlet temperature sensors for proper installation. Refer to Air Temperature Sensor Replacement - Upper Auxiliary and Air Temperature Sensor Replacement - Lower Auxiliary . Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 11 |
| 11 | Place your hand directly over the infrared sensor on the rear auxiliary HVAC control module. Do the counts change? |
- | Go to Step 12 | Go to Step 18 |
| 12 |
|
- | System OK | Go to Step 16 |
| 13 | Test the low reference circuit of the front auxiliary HVAC control assembly for an open or high resistance. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 15 |
| 14 | Test the front auxiliary temperature door control circuit of the front auxiliary HVAC control assembly for an open or high resistance. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 15 |
| 15 |
|
- | Go to Step 18 | Go to Step 17 |
| 16 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 19 |
| 17 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 20 |
| 18 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 22 | Go to Step 21 |
| 19 | Replace the suspect air temperature sensor. Refer to Air Temperature Sensor Replacement - Upper Auxiliary or Air Temperature Sensor Replacement - Lower Auxiliary . Did you complete the replacement? |
- | Go to Step 22 | - |
| 20 | Replace the front auxiliary HVAC control assembly. Refer to HVAC Control Assembly Replacement - Front Auxiliary . Did you complete the replacement? |
- | Go to Step 22 | - |
| 21 | Replace the auxiliary HVAC control module. Refer to HVAC Control Module Replacement - Auxiliary . Did you complete the replacement? |
- | Go to Step 22 | - |
| 22 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |