Test Description
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2002 GMC Yukon XL, 2002 GMC Yukon, 2002 Chevrolet Tahoe, 2002 Chevrolet Suburban, and 2002 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
The number below refers to the step numbers on the diagnostic table.
- 2: The scan tool uses a default value. This will not give an accurate reading of the sensor value if an open or a short to ground is detected.
DTC B0184
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference : HVAC Schematics | ||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
5 V | Go to Step 3 | Go to Step 4 |
| 3 | Measure the voltage from the sunload sensor signal circuit to the low reference circuit of the sunload sensor. Does the voltage measure near the specified value? |
5 V | Go to Step 6 | Go to Step 5 |
| 4 | Test the signal circuit of the sunload sensor for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to CIRCUIT TESTING
and to WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 7 |
| 5 | Test the low reference circuit of the sunload sensor for a high resistance or for an open. Refer to CIRCUIT TESTING
and to WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 7 |
| 6 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and to CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 8 |
| 7 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and to CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 9 |
| 8 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? |
- | Go to Step 10 | - |
| 9 |
IMPORTANT:
Perform the calibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement .Did you complete the replacement? |
- | Go to Step 10 | - |
| 10 |
|
- | Go to Step 2 | System OK |