Test Description
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2002 GMC Yukon XL, 2002 GMC Yukon, 2002 Chevrolet Tahoe, 2002 Chevrolet Suburban, and 2002 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
The number below refers to the step numbers on the diagnostic table.
- 2: The scan tool uses a default value. This will not give an accurate reading of the sensor value if an open or a short to ground is detected.
DTC B0164
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference : HVAC Schematics | ||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
5 V | Go to Step 3 | Go to Step 4 |
| 3 | Measure the voltage from the signal circuit to the low reference circuit of the inside air temperature sensor. Does the voltage measure near the specified value? |
5 V | Go to Step 6 | Go to Step 5 |
| 4 | Test the signal circuit of the inside air temperature sensor for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to CIRCUIT TESTING
and to WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 11 | Go to Step 8 |
| 5 | Test the low reference circuit of the inside air temperature sensor for a high resistance or for an open. Refer to CIRCUIT TESTING
and to WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 11 | Go to Step 8 |
| 6 | Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and to CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 11 | Go to Step 7 |
| 7 | Test the resistance of the inside air temperature sensor. Refer to Sensor Resistance Table (Ambient and Inside Air Temp - ohms) or Sensor Resistance Table (Upper, Lower and Aux Air Temp - ohms) . Is the resistance measurement approximately equal to the Sensor Resistance Table value? |
- | Go to Step 8 | Go to Step 9 |
| 8 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and to CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 11 | Go to Step 10 |
| 9 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? |
- | Go to Step 11 | - |
| 10 |
IMPORTANT:
Perform the calibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement .Did you complete the replacement? |
- | Go to Step 11 | - |
| 11 |
|
- | Go to Step 2 | System OK |